ACT-457A Panel PC Page i IEI Technology Corp. User Manual MODEL: ACT-457A Panel PC with Touch Screen and 500 MHz Alchemy AU1250Gigabit Ethernet, 2
ACT-457A Panel PC Page 2 1.1 Introduction Figure 1-1: ACT-457A The ACT-457A is an 500 MHz Alchemy AU1250 powered access control terminal with a RFI
ACT-457A Panel PC Page 3 500 MHz Alchemy AU1250 system processor Built-in RFID reader supports Mifare card and EM card read/write 256 MB DD
ACT-457A Panel PC Page 4 1.4 External Overview The diagrams below detail all the parts and connectors on the ACT-457A. Figure 1-2: Front View
ACT-457A Panel PC Page 5 Figure 1-3: Front View (Faceplate Removed) Figure 1-4: Rear Panel VESA Mounting Holes
ACT-457A Panel PC Page 6 Figure 1-5: Bottom I/O Figure 1-6: Top I/O Figure 1-7: CompactFlash® Card Slot 1.5 Internal Parts The ACT-457A has the
ACT-457A Panel PC Page 7 2 x Microphones 1.6 Specifications The technical specifications for the ACT-457A system are listed in Table 1-1. Specifi
ACT-457A Panel PC Page 8 Specification ACT-457A Construction Material ABS + PC plastic front frame Aluminum alloy chassis Front Panel Color Blue
ACT-457A Panel PC Page 9 1.7 Dimensions The dimensions of the ACT-457A are shown below. Figure 1-8: Front Dimensions
ACT-457A Panel PC Page 10 Figure 1-9: Front Dimensions
ACT-457A Panel PC Page 11 Figure 1-10: Cutout Dimensions
ACT-457A Panel PC Page ii Revision Date Version Changes 15 December 2009 1.02 Changed rear panel screw picture in Figure 4-1 15 December 2009 1.0
ACT-457A Panel PC Page 12 Chapter 2 2 Installation
ACT-457A Panel PC Page 13 2.1 Unpacking To unpack the access control terminal, follow the steps below: WARNING! The front side LCD screen has a pro
ACT-457A Panel PC Page 14 2.2 Packing List The ACT-457A access control terminal is shipped with the following components: Quantity Item Image 1 AC
ACT-457A Panel PC Page 15 2.3 Installation and Configuration Steps The following installation steps must be followed. Step 1: Unpack the ACT-457A S
ACT-457A Panel PC Page 16 2.5 SD Card Installation The ACT-457A has a single SD card slot. To install the SD card, follow the steps below. Step 1:
ACT-457A Panel PC Page 17 2.6 System Power The system can be run in the AT power mode or the ATX power mode. Both these power modes are described
ACT-457A Panel PC Page 18 Step 2: Carefully mark the locations of the four screw holes in the bracket on the wall. Step 3: Drill four pilot hole
ACT-457A Panel PC Page 19 Figure 2-5: Chassis Support Screws NOTE: In the diagram below the bracket is already installed on the wall. Step 9: Se
ACT-457A Panel PC Page 20 Figure 2-6: Secure the ACT-457A 2.7.2 In-wall Mounting To mount the ACT-457A into a wall follow the directions below. Ste
ACT-457A Panel PC Page 21 Step 2: Cut the adhesive foam tape as shown above. Figure 2-8: Attach Foam Tape Step 3: Attach the adhesive foam tape t
ACT-457A Panel PC Page iii Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve
ACT-457A Panel PC Page 22 Step 5: Cut out hole with the dimensions shown below. Take care that the wall section that is cut out is no larger than t
ACT-457A Panel PC Page 23 Step 7: Tighten the screws that pass through the wall mounting screw holes until the screws are firmly secured to the wal
ACT-457A Panel PC Page 24 NOTE: When purchasing the arm please ensure it has a 75 mm x 75 mm mounting hole pattern. Only this mounting size will su
ACT-457A Panel PC Page 25 PC.Step 0: 2.8 Bottom Panel Connectors Before operating the ACT-457A, connect the peripheral devices listed below. 2.8.1 L
ACT-457A Panel PC Page 26 Step 1: Locate the DB-9 connector. The location of the DB-9 connector is shown in Chapter 2. Step 2: Insert the serial c
ACT-457A Panel PC Page 27 Figure 2-16: USB Device Connection Step 3: Insert the device connector. Once aligned, gently insert the USB device conne
ACT-457A Panel PC Page 28 CAUTION: 1. Digital input A. The system includes a digital input power source B. Digital input must be less than 50 V
ACT-457A Panel PC Page 29 Figure 2-17: Digital I/O Cable Installation
ACT-457A Panel PC Page 30 Chapter 3 3 RFID Reader
ACT-457A Panel PC Page 31 3.1 Introduction The RFID tool is used to configure Mifare cards and EM cards. 3.2 Installation The RF320 RFID application
ACT-457A Panel PC Page iv Table of Contents 1 INTRODUCTION...
ACT-457A Panel PC Page 32 Label Description Allows the user to select the serial port used by the ACT-457A to communicate with the RFID reader modu
ACT-457A Panel PC Page 33 Figure 3-2: RF320 COM Port Settings NOTE: If the Hyper Terminal is used for communication, please setup the port proper
ACT-457A Panel PC Page 34 The following sections describe how to use these commands. 3.5.1 Read Block To read the block data from a Mifare card, ple
ACT-457A Panel PC Page 35 Field Command Block KEY KEY Data Time Out End Data RB 00~63 A/B 000000000000 ︴(Hex) FFFFFFFFFFFF00~99 (Second) C
ACT-457A Panel PC Page 36 Figure 3-4: Write Block Field Command Block KEY KEY Data Time Out Block Data End Digit 2 2 1 12 2 32 1 Data
ACT-457A Panel PC Page 37 Step 2: Select a Mifare mode. 0-UUID: read serial number only. 1-UUID & KEY A: read serial number and use "
ACT-457A Panel PC Page 38 Status (2 digits) Block Data END (2 digits) OK Null CR,LF (0x0d,0x0a) ER Error Code (3 digits) CR,LF (0x0d,0x0a) Ta
ACT-457A Panel PC Page 39 Field Command End Data RM CR (0x0d) Table 3-9: Get Mifare Parameter Raw Data Format Status (2 digits) Block Data E
ACT-457A Panel PC Page 40 Figure 3-7: Set RF-320 Mode Field Command Mode End Digit 2 1 1 Data SA 1~3 CR (0x0d) Table 3-11: Set RF320 Mode R
ACT-457A Panel PC Page 41 Chapter 4 4 System Maintenance
ACT-457A Panel PC Page v 3.3 RF320 INTERFACE OVERVIEW... 31 3.4 SERIA
ACT-457A Panel PC Page 42 4.1 System Maintenance Introduction If the components of the ACT-457A fail they must be replaced. Components that can be r
ACT-457A Panel PC Page 43 4.3 Turn off the Power WARNING: Failing to turn off the system before opening it can cause permanent damage to the system
ACT-457A Panel PC Page 44 4.5 Replacing Components The ACT-457A contains no user-serviceable parts. Certain components on the ACT-457A can be replac
ACT-457A Panel PC Page 45 Appendix A A External Connector Pinouts
ACT-457A Panel PC Page 46 A.1 Introduction Pin out signal definitions for the external connectors are provided in this appendix. A.2 Digital I/O Con
ACT-457A Panel PC Page 47 Pin Description Pin Description 1 X1+ 2 X1- 3 X2+ 4 X2- 5 VCC2_5 6 GND 7 X3+ 8 X3- 9 X4+ 10 X4- 11 X1- 12 ACT
ACT-457A Panel PC Page 48 Pin Description Pin Description 1 DCD3/TX3-/D- 6 DSR3/RX1- 2 RX3/TX3+/D+ 7 RTS3/RX1+ 3 TX3 8 CTS3 4 DTR3 9 RI3 5 GND
ACT-457A Panel PC Page 49 Appendix B B Terminology
ACT-457A Panel PC Page 50 AC ’97 Audio Codec 97 (AC’97) refers to a codec standard developed by Intel® in 1997. ACPI Advanced Configuration and Powe
ACT-457A Panel PC Page 51 DMA Direct Memory Access (DMA) enables some peripheral devices to bypass the system processor and communicate directly wit
ACT-457A Panel PC Page vi List of Figures Figure 1-1: ACT-457A ...
ACT-457A Panel PC Page 52 LCD Liquid crystal display (LCD) is a flat, low-power display device that consists of two polarizing plates with a liquid
ACT-457A Panel PC Page 53 Appendix C C Watchdog Timer
ACT-457A Panel PC Page 54 NOTE: The following discussion applies to DOS environment. IEI support is contacted or the IEI website visited for specif
ACT-457A Panel PC Page 55 NOTE: When exiting a program it is necessary to disable the Watchdog Timer, otherwise the system resets. EXAMPLE PROGRAM:
ACT-457A Panel PC Page 56 Appendix D D Hazardous Materials Disclosure
ACT-457A Panel PC Page 57 D.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002/95/EC Without Mercury The
ACT-457A Panel PC Page 58 Toxic or Hazardous Substances and Elements Part Name Lead (Pb) Mercury (Hg) Cadmium(Cd) Hexavalent Chromium(CR(VI)) Polybr
ACT-457A Panel PC Page 59 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的年限。本产品可能包含有较短的环境友好
ACT-457A Panel PC Page vii Figure 3-4: Write Block ...
ACT-457A Panel PC Page viii List of Tables Table 1-1: System Specifications......
ACT-457A Panel PC Page 1 Chapter 1 1 Introduction