RPC-6010G Rackmount LCD Workstation Page i
RPC-6010G Rackmount LCD WorkstationList of Tables Table 1-1: RPC-6010G Model Variations...
RPC-6010G Rackmount LCD Workstation 1 Introduction Chapter 1 Page 1
RPC-6010G Rackmount LCD Workstation1.1 RPC-6010G Overview The RPC-6010G is a PC/AT compatible computer designed for industrial applications. It has a
RPC-6010G Rackmount LCD Workstation Model Touch Screen SBC Form Factor Expansion Slots ACE-R4140AP Redundant Power Supply RPC-6010GWR/ACE-R4140AP No
RPC-6010G Rackmount LCD WorkstationTHIS PAGE IS INTENTIONALLY LEFT BLANK Page 4
RPC-6010G Rackmount LCD Workstation 2 Mechanical Overview Chapter 2 Page 5
RPC-6010G Rackmount LCD Workstation2.1 External Overview The following sections describe the physical layout of the RPC-6010G rackmount workstation.
RPC-6010G Rackmount LCD Workstation Figure 2-2: RPC-6010G Front Panel Door Open (Drives Not Included) 2.1.2 Rear Panel The RPC-6010G rackmount workst
RPC-6010G Rackmount LCD WorkstationFigure 2-3: RPC-6010G 14 Slot Rear Panel 2.1.2.2 ATX Motherboard Rear Panel The RPC-6010G rackmount workstation is
RPC-6010G Rackmount LCD Workstation Figure 2-4: RPC-6010G ATX Motherboard Rear Panel 2.1.3 Right Side Panel The RPC-6010G rackmount workstation has t
RPC-6010G Rackmount LCD WorkstationRevision MODEL RPC6010G Rackmount Workstation Revision Number Description Date of Issue 1.0 Initial release D
RPC-6010G Rackmount LCD Workstation2.1.4 Left Side Panel The RPC-6010G rackmount workstation has the following left side panel items: Cooling vent
RPC-6010G Rackmount LCD Workstation 2.2.2 RPC-6010G Physical Dimensions The physical dimensions of the RPC-6010G are shown in Figure 2-1. Figure 2-
RPC-6010G Rackmount LCD WorkstationTHIS PAGE IS INTENTIONALLY LEFT BLANK Page 12
RPC-6010G Rackmount LCD Workstation 3 Detailed Specifications Chapter 3 Page 13
RPC-6010G Rackmount LCD Workstation3.1 RPC-6010G Specifications Table 3-1 shows the RPC-6010G specifications. LCD Type 8.4" TFT Input Interface
RPC-6010G Rackmount LCD Workstation 3.2 LCD Specifications Table 3-2 lists the RPC-6010G LCD specifications. Size 8.4” MFR/Model AUO/G084SN03 Resolut
RPC-6010G Rackmount LCD Workstation3.3 ACE-832AP PSU Specifications Table 3-3 lists the ACE-832AP power supply specifications. INPUT Voltage 90 ~ 2
RPC-6010G Rackmount LCD Workstation 4 Installation Chapter 4 Page 17
RPC-6010G Rackmount LCD Workstation4.1 Installation Considerations 4.1.1 Installation Precautions When installing the RPC-6010G, please follow the pr
RPC-6010G Rackmount LCD Workstation Backplane/Motherboard: The backplane or motherboard installed in the RPC-6010G rackmount workstation is separa
RPC-6010G Rackmount LCD Workstation Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to
RPC-6010G Rackmount LCD WorkstationStep 3: Step 4: Step 5: Step 6: Step 7: Use box cutters, a knife or a sharp pair of scissors to open the top of th
RPC-6010G Rackmount LCD Workstation Quantity Description Image 2 Handle bracket 1 Mini-DIN 6 PS/2 connector cable 1 Power cable 1 Screw kit 7 S
RPC-6010G Rackmount LCD Workstation4.3 Pre-installation Preparation 4.3.1 System Planning User supplied CPU cards and backplanes or motherboards need
RPC-6010G Rackmount LCD Workstation 4.4 Installation Procedures 4.4.1 Preinstalled Components The following components are preinstalled in the RPC-60
RPC-6010G Rackmount LCD WorkstationStep 10: Step 11: Step 12: Step 13: Step 14: Connect all required cables. Reinstall the dual CPU card clamp and dr
RPC-6010G Rackmount LCD Workstation 4.5.1 Remove the Top Cover The top cover is secured to the RPC-6010G rackmount workstation with six screws (three
RPC-6010G Rackmount LCD Workstation4.5.2 Remove the CPU Card Clamp The CPU card clamp is secured to the RPC-6010G rackmount workstation with four ret
RPC-6010G Rackmount LCD Workstation Figure 4-4: Dual CPU Card Clamp and Drive Bay Stabilizer Bracket Right Side Retention Screws (Left Side Sim
RPC-6010G Rackmount LCD WorkstationStep 3: Step 1: Remove the CPU card clamp and drive bay bracket from the chassis.Step 0: 4.5.4 Remove the Drive B
RPC-6010G Rackmount LCD Workstation Figure 4-7: Drive Slot Blank Plate Retention Screws (Other Side Similar) Step 2: Step 1: Step 2: Step 3: Step 4:
RPC-6010G Rackmount LCD WorkstationPacking List NOTE: If any of the components listed in the checklist below are missing, please do not proceed wit
RPC-6010G Rackmount LCD WorkstationStep 5: Insert the appropriate number of retention screws into each side of the 5.25” disk drive through the driv
RPC-6010G Rackmount LCD Workstation Figure 4-9: 3.5” to 5.25” Drive Bay Rack Retention Screws (Other Side Similar) Step 3: Step 4: Step 5: Step 6: S
RPC-6010G Rackmount LCD WorkstationStep 4: Step 5: Slide a 3.5” disk drive into one of the 3.5” drive brackets. Make sure the connectors of the drive
RPC-6010G Rackmount LCD Workstation 4.5.8 Install the Backplane To install a backplane, follow the instructions below. Step 1: Install the correct a
RPC-6010G Rackmount LCD WorkstationStep 2: Step 3: Step 4: Mount the backplane into the chassis. Make sure the backplane is positioned so that when t
RPC-6010G Rackmount LCD Workstation 4.5.9 Install the CPU Card CAUTION Before a CPU card is inserted into the backplane, make sure the CPU card has
RPC-6010G Rackmount LCD WorkstationFigure 4-13: Slot Cover Retention Screw Step 2: Step 3: Step 4: Remove the CPU card clamp. (See Section 4.5.2) Rem
RPC-6010G Rackmount LCD Workstation Figure 4-14: Install the CPU Card Step 5: Step 6: Step 1: To secure the CPU card, reinsert the previously removed
RPC-6010G Rackmount LCD WorkstationStep 2: Step 3: Step 4: Step 5: Step 1: Step 2: Step 3: Step 4: Step 5: If necessary, remove the CPU card clamp. (
RPC-6010G Rackmount LCD Workstation Figure 4-15: Installing a Short Card 4.5.12 Connect the Cables The following cables may have to be connected dep
RPC-6010G Rackmount LCD Workstation Table of Contents 1 INTRODUCTION...
RPC-6010G Rackmount LCD Workstation4.5.13 Close the Top Cover Before closing the top cover, make sure the following items have been completed: T
RPC-6010G Rackmount LCD Workstation NOTE: This section gives a generic description of the rack mounting process for the RPC-6010G rackmount worksta
RPC-6010G Rackmount LCD WorkstationStep 2: Remove the rack slides from the rack slide brackets. (See Figure 4-17) Figure 4-17: Remove Rack Slide St
RPC-6010G Rackmount LCD Workstation Figure 4-18: Workstation Slide Installation (Other Side Similar) Step 4: Assemble the slide brackets per the ma
RPC-6010G Rackmount LCD Workstation Figure 4-19: Rack Slide Bracket Assembly Step 5: Attach the slide brackets to the rack per the manufacturer’s in
RPC-6010G Rackmount LCD Workstation Figure 4-20: Rack Slide Bracket Installation Step 6: Insert the workstation with the attached slides into the r
RPC-6010G Rackmount LCD WorkstationFigure 4-21: Install Workstation into Rack Step 7: If necessary, secure the workstation handle brackets to the ra
RPC-6010G Rackmount LCD Workstation 5 Maintenance Chapter 5 Page 47
RPC-6010G Rackmount LCD Workstation5.1 Maintenance Overview Maintaining the RPC-6010G rackmount workstation is essential for the smooth operating of
RPC-6010G Rackmount LCD Workstation Step 3: Step 4: Step 5: Step 6: Step 7: Step 8: Step 9: Step 10: Step 11: Step 12: Step 13: Step 1: Step 2: Step
RPC-6010G Rackmount LCD Workstation4.2.3 Packing List ...
RPC-6010G Rackmount LCD WorkstationStep 5: Step 6: Step 7: Step 8: Step 9: Step 10: Step 11: Step 12: Step 13: Step 1: Step 2: Step 3: Step 4: Step 5
RPC-6010G Rackmount LCD Workstation Step 7: Step 8: Step 9: Step 10: Step 11: Step 12: Step 13: Step 1: Step 2: Step 3: Step 4: Step 5: Step 6: Remov
RPC-6010G Rackmount LCD Workstation Figure 5-1: PSU External Retention Screws Step 7: Remove the two internal retention screws that secure the PSU a
RPC-6010G Rackmount LCD Workstation Step 8: Remove the two retention screws on the PSU mounting bracket (Figure 5-3). Figure 5-3: PSU Mounting Brac
RPC-6010G Rackmount LCD Workstation5.6 Cooling Fan Replacement To replace a cooling fan, please follow the instructions below. CAUTION: Carefully n
RPC-6010G Rackmount LCD Workstation Figure 5-4: Cooling Fan Bracket External Screws Step 9: Remove the three retention screws that secure the cooli
RPC-6010G Rackmount LCD WorkstationStep 10: Remove the fan from the bracket by removing the four retention screws. (See Figure 5-6) Figure 5-6: Fan
RPC-6010G Rackmount LCD Workstation Step 18: Step 19: Step 1: Step 2: Step 3: Step 4: Step 5: Step 6: Step 7: Step 8: Step 9: Step 10: Step 11: Step
RPC-6010G Rackmount LCD Workstation5.7.2 5.25” Disk Drive Replacement To replace a 5.25” disk drive, please follow the instructions below. NOTE: Th
RPC-6010G Rackmount LCD Workstation 6 On Screen Display (OSD) Controls Chapter 6 Page 59
RPC-6010G Rackmount LCD Workstation 5.7.1 3.5” Disk Drive Replacement ... 57 5
RPC-6010G Rackmount LCD Workstation6.1 User Mode OSD Structure 6.1.1 OSD Buttons There are several on-screen-display (OSD) control buttons on the fro
RPC-6010G Rackmount LCD Workstation 6.1.2 OSD Menu Structure Table 6-1 shows the OSD menu structure. Level 0 Level 1 Value Brightness 0 to 100 Cont
RPC-6010G Rackmount LCD WorkstationLevel 0 Level 1 Value Digital Signal Menu Analog Select Light Enable On or Off Light Contrast 0 to 100 Light B
RPC-6010G Rackmount LCD Workstation Brightness: The brightness option adjusts the brightness of screen. This function adjusts the offset value o
RPC-6010G Rackmount LCD Workstation6.2.2 Color Color options are shown in Figure 6-3. Figure 6-3: Color Options The Color menu fine-tunes the palett
RPC-6010G Rackmount LCD Workstation 6.2.3 Language The Languages are shown in Figure 6-4. Figure 6-4: Language Menu This menu provides options for s
RPC-6010G Rackmount LCD Workstation6.2.4 OSD Configurations The OSD configurations are shown in Figure 6-5. Figure 6-5: OSD Configurations Menu OSD
RPC-6010G Rackmount LCD Workstation Aspect Ratio Adjusts the display ratio referring to the width of the screen and then to the height of the scre
RPC-6010G Rackmount LCD Workstation6.2.6 Backlight The Backlight menu in Figure 6-7 enables users to configure the LCD backlight. Figure 6-7: Backli
RPC-6010G Rackmount LCD Workstation Chapter 7 7 Software Driver Page 69
RPC-6010G Rackmount LCD WorkstationList of Figures Figure 2-1: RPC-6010G Front Panel ...
RPC-6010G Rackmount LCD Workstation NOTE: The following information is provided for workstations with touch screens. 7.1 Touch Screen Driver The tou
RPC-6010G Rackmount LCD Workstation 7.2 Driver Installation To install the touch screen software driver, please follow the steps below. Step 1: Step
RPC-6010G Rackmount LCD WorkstationStep 4: Once the OS system is selected, the touch kit setup will prepare the install shield wizard (Figure 7-2).
RPC-6010G Rackmount LCD Workstation Step 7: An Install PS/2 interface driver screen appears (Figure 7-4). It is not necessary to install the PS/2 in
RPC-6010G Rackmount LCD WorkstationFigure 7-5: Install PS/2 Interface Driver Step 9: The user is then prompted to ensure the touch monitor or the
RPC-6010G Rackmount LCD Workstation Step 10: The user is then prompted to select multi-monitor system support (Figure 6-7). Make the appropriate sel
RPC-6010G Rackmount LCD WorkstationStep 11: The user is then prompted to select a file directory in which the touch kit controller is installed (Fig
RPC-6010G Rackmount LCD Workstation Step 12: The user is then prompted to select a file directory in which the program icons are saved (Figure 7-9).
RPC-6010G Rackmount LCD WorkstationStep 13: The program then starts installing (Figure 7-10). Figure 7-10: Installing Page 78
RPC-6010G Rackmount LCD Workstation Step 14: Once the program is finished installing, the user is prompted to restart the computer now or to restart
RPC-6010G Rackmount LCD Workstation Figure 4-21: Install Workstation into Rack ...46 Figu
RPC-6010G Rackmount LCD WorkstationTHIS PAGE IS INTENTIONALLY LEFT BLANK Page 80
RPC-6010G Rackmount LCD Workstation A Certifications Appendix A Page 81
RPC-6010G Rackmount LCD WorkstationA.1 RoHS Compliant All RPC-6010G rackmount workstations comply with the Restriction of Hazardous Materials (RoHS)
RPC-6010G Rackmount LCD Workstation B Recommended IEI Backplanes, Motherboards and PSUs Appendix B Page 83
RPC-6010G Rackmount LCD WorkstationThe following IEI backplanes, motherboards and power supply units are recommended for the RPC-6010G rackmount work
RPC-6010G Rackmount LCD Workstation B.2 Recommended IEI Power Supply Units The following table lists the recommended IEI power supply units for the R
RPC-6010G Rackmount LCD WorkstationTHIS PAGE IS INTENTIONALLY LEFT BLANK Page 86
RPC-6010G Rackmount LCD Workstation C Index Page 87
RPC-6010G Rackmount LCD Workstation Installation Steps ...23 A PCI/ISA Expansion Card ...37 Preca
RPC-6010G Rackmount LCD Workstation N Number of Colors...........15 O On Screen Display (OSD) .......59