ICE-PV-N4551_D5251 COM Express Type 2 Module Page 1Chapter 1 1 Introduction
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 2 1.1 Overview Figure 1–1: ICE-PV-N4551/D5251 The ICE-PV-N4551/D5251 COM Express module provides t
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 31.1.2 Benefits Some of the ICE-PV-N4551/D5251 embedded platform benefits include: Low power, h
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 4 1.2 Dimensions The dimensions of the board are listed below: Length: 95 mm Width: 95 mm 1.2
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 51.2.2 Side View The figure below shows the dimensions as viewed from the side. Figure 1-3: Side
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 6 1.3 Data Flow Figure 1-4 shows the data flow between the two on-board chipsets and other componen
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 71.4 Connectors The ICE-PV-N4551/D5251 embedded module has the following connectors as seen in Fig
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 8 Figure 1-6: ICE-PV-N4551/D5251 Overview (Reverse Side) 1.4.1 IO Interface Support The ICE-PV-N45
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 9 HD Audio (through HD audio chip on the baseboard, connected to HD audio interface on the ICE-P
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage ii Revision Date Version Changes 3 April, 2012 1.02 Minor correction to Table 3-1: ICE-PV-N4551/D
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 10 Specification Value Watchdog Timer Software programmable supports 1~255 sec. system resetPhysic
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 11Chapter 2 2 Unpacking
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 12 2.1 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 132.3 Unpacking Checklist NOTE: If some of the components listed in the checklist below are missi
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 14 Quantity Item Image 1 Utility CD Table 2-1: Package List Contents
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 15Chapter 3 3 Connectors
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 16 3.1 Peripheral Interface Connectors Section 3.1.1 shows interface connector locations. Section
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 17 Figure 3-2: Connector and Jumper Locations (Back Side) 3.1.2 Peripheral Interface Connectors Ta
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 18 3.2 Peripheral Interface Connectors The location of the pins and the pinout descriptions of the
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 19Pin No. Description Pin No. Description C1 GND D1 GND C2 IDE_D7 D2 IDE_D5 C3
ICE-PV-N4551_D5251 COM Express Type 2 Module Page iiiCopyright COPYRIGHT NOTICE The information in this document is subject to change without prior
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 20 Pin No. Description Pin No. Description C33 PCI_C/BE1# D33 PCI_SERR# C34 PCI_PERR#
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 21Pin No. Description Pin No. Description C65 PEG_RX4+ D65 PEG_TX4+ C66 PEG_RX4- D66
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 22 Pin No. Description Pin No. Description C97 RSVD D97 PEG_ENABLE# C98 PEG_RX14+ D98
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 23 Figure 3-4: COM Express Connector AB Location Pin No. Description Pin No. Description A1
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 24 Pin No. Description Pin No. Description A13 GBE0_MDI0+ B13 SMB_CK A14 GBE0_CTREF B
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 25Pin No. Description Pin No. Description A45 USB0- B45 USB1- A46 USB0+ B46 USB1+ A
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 26 Pin No. Description Pin No. Description A77 LVDS_VDD_EN B77 LVDS_B3+ A78 LVDS_A3+ B
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 27Pin No. Description Pin No. Description A109 +V12 B109 +V12 A110 GND B110 GND T
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 28 CN Type: 6-pin connector CN Location: See Figure 3-6 CN Pinouts: See Table 3-4 The SPI connector
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 29Pin No. Description 6 SPI_VCC (+3.3V) Table 3-4: SPI Flash Connector Pin Definitions
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage iv Packing List NOTE: If any of the components listed in the checklist below are missing, please d
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 30 Chapter 4 4 Installation
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 314.1 Installation Considerations NOTE: The following installation notices and installation consi
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 32 4.2 Unpacking NOTE: If any of the items listed below are missing when the ICE-PV-N4551/D5251 is
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 33If one or more of these items are missing, please contact the reseller or vendor the ICE-PV-N455
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 34 4.4 Jumper Settings NOTE: A jumper is a metal bridge used to close an electrical circuit. It
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 354.4.1 LVDS Panel Resolution Jumper Label: SW1 Jumper Type: 4-in-1 switch Jumper Settings: See T
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 36 WARNING! Please note that the installation instructions described in this manual should be care
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 37Chapter 5 5 BIOS Setup
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 38 5.1 Introduction NOTE: The BIOS items shown below are from an ICE-PV-N4551/D5251 installed on t
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 39Key Function Right arrow Move to the item on the right hand side + Increase the numeric value
ICE-PV-N4551_D5251 COM Express Type 2 Module Page vTable of Contents 1 INTRODUCTION...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 40 Security – Sets User and Supervisor Passwords. Save & Exit – Selects exit options and
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 41The System Overview field also has two user configurable fields: System Date [xx/xx/xx] Use t
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 42 Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Main Advanced Chipset Boot
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 43 ACPI Sleep State [S1 (CPU Stop Clock)] Use the ACPI Sleep State option to specify the sleep s
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 44 Processor Type: Lists the brand name of the CPU being used EMT64: Indicates if the EM64T i
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 455.3.3 IDE Configuration Use the IDE Configuration menu (3BIOS Menu 5) to change and/or set the c
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 46 AHCI Configures SATA devices as AHCI device. 5.3.4 USB Configuration Use the USB Configuratio
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 47 Disabled USB 2.0 (EHCI) support disabled Enabled DEFAULT USB 2.0 (EHCI) support enabled
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 48 Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced PC He
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 495.3.6 Secondary Super IO Configuration The Secondary Super IO Configuration menu (BIOS Menu 8) d
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage vi 4.1 INSTALLATION CONSIDERATIONS...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 50 IO=2C0h; IRQ=10 Serial Port I/O port address is 2C0h and the interrupt address is IRQ10 IO=
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 51 IO=2D0h; IRQ=10, 11 Serial Port I/O port address is 2D0h and the interrupt address is IRQ10,
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 52 5.3.6.4 COM 6 Configuration Serial Port [Enabled] Use the Serial Port option to enable or dis
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 535.3.7 Super IO Configuration Use the Super IO Configuration menu (3BIOS Menu 9) contains the sub
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 54 Device Mode [Read Write] Use the Device Mode option to set the floppy disk controller mode.
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 55 IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 3E8h and the interrupt
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 56 IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12 Serial Port I/O port address is 3F8h and the interrupt
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 57 IO=378h; IRQ=5 Serial Port I/O port address is 378h and the interrupt address is IRQ5 IO=37
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 58 Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced WinBo
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 595.3.9 Serial Port Console Redirection The Serial Port Console Redirection menu (3BIOS Menu 11)
ICE-PV-N4551_D5251 COM Express Type 2 Module Page vii5.4 CHIPSET ...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 60 VT100 The target terminal type is VT100 VT100+ The target terminal type is VT100+ VT-UTF
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 61Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Main Advanced Chipset Boot
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 62 Share Memory Size [8 MB] Use the Share Memory Size option to set the amount of system memory
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 635.4.2 South Bridge Configuration Use the South Bridge Configuration menu (3BIOS Menu 14) to conf
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 64 Enabled DEFAULT The onboard High Definition Audio controller automatically detected and enable
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 65 DVMT Mode DEFAULT Graphics memory is dynamically allocated according to the system and graphi
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 66 5.5 Boot Use the Boot menu (3BIOS Menu 16) to configure system boot options. Aptio Setup Utility
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 67 Quiet Boot [Disabled] Use the Quiet Boot BIOS option to select the screen display when the sy
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 68 Administrator Password Use the Administrator Password to set or change an administrator passw
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 69 Save Changes and Reset Use the Save Changes and Reset option to save the changes made to th
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage viii List of Figures Figure 1–1: ICE-PV-N4551/D5251...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 70 Chapter 6 6 Software Installation
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 716.1 Available Software Drivers NOTE: The content of the CD may vary throughout the life cycle o
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 72 Step 2: The screen in Figure 6-1 appears. Figure 6-1: Start Up Screen Step 3: Click ICE-PV-N4
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 73 Figure 6-2: Drivers Step 5: Install the necessary drivers from the list. Step 0:
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 74 Appendix A A BIOS Options
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 75Below is a list of BIOS configuration options in the BIOS chapter. BIOS Information ...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 76 Device Mode [Printer Mode]...
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 77Appendix B B Terminology
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 78 AC ’97 Audio Codec 97 (AC’97) refers to a codec standard developed by Intel® in 1997. ACPI Advan
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 79DMA Direct Memory Access (DMA) enables some peripheral devices to bypass the system processor an
ICE-PV-N4551_D5251 COM Express Type 2 Module Page ixList of Tables Table 1-1: Technical Specifications...
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 80 LCD Liquid crystal display (LCD) is a flat, low-power display device that consists of two polari
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 81Appendix C C Watchdog Timer
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 82 NOTE: The following discussion applies to DOS environment. IEI support is contacted or the IEI
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 83 NOTE: When exiting a program it is necessary to disable the Watchdog Timer, otherwise the syste
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 84 Appendix D D Hazardous Materials Disclosure
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 85D.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002
ICE-PV-N4551_D5251 COM Express Type 2 ModulePage 86 Toxic or Hazardous Substances and Elements Part Name Lead (Pb) Mercury (Hg) Cadmium(Cd) Hexavale
ICE-PV-N4551_D5251 COM Express Type 2 Module Page 87此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会