TANK-6000-C226 Embedded System Page i User Manual , MODEL: TANK-6000-C226 Embedded s ystem supports 22nm LGA1155 Intel® Xeon® E3 / Core™ i3 CPU, H
TANK-6000-C226 Embedded System Page x Lis t of Tables Table 1-1: Model Variations ...
TANK-6000-C226 Embedded System Page 90 Figure C-2: Launching the Recovery Tool Step 3: The recovery tool setup menu is shown as below. Figure C
TANK-6000-C226 Embedded System Page 91 Figure C-4: Command Prompt Step 5: The command prompt window appears. Type the following commands (marked i
TANK-6000-C226 Embedded System Page 92 Figure C-5: Partition Creation Commands
TANK-6000-C226 Embedded System Page 93 NOTE: Use the following commands to check if the partitions were created successfully. Step 6: Press an
TANK-6000-C226 Embedded System Page 94 C.2.4 Building the Recovery Partition Step 1: Put the recover CD in the optical drive. Step 2: Start the sy
TANK-6000-C226 Embedded System Page 95 Step 5: The Symantec Ghost window appears and starts configuring the system to build a recovery partition. I
TANK-6000-C226 Embedded System Page 96 C.2.5 Create Factory Default Im a g e NOTE: Before creating the factory default image, please configure th
TANK-6000-C226 Embedded System Page 97 Figure C-12: About Symantec Ghost Window Step 4: Use mouse to navigate to the option shown below (Figure C-
TANK-6000-C226 Embedded System Page 98 Figure C-14: Select a Local Source Drive Step 6: Select a source partition (Part 1) from basic drive as sho
TANK-6000-C226 Embedded System Page 99 Figure C-16: File Name to Copy Image to Step 8: When the Compress Image screen in Figure C-17 prompts, clic
TANK-6000-C226 Embedded System Page 1 Chapter 1 1 Introduction
TANK-6000-C226 Embedded System Page 100 Step 9: The Proceed with partition image creation window appears, click Yes to continue. Figure C-18: Imag
TANK-6000-C226 Embedded System Page 101 Step 12: The recovery tool main menu window is shown as below. Press any key to reboot the system. St ep
TANK-6000-C226 Embedded System Page 102 Figure C-22: Auto Recovery Utility Step 3: Reboot the system from the recovery CD. When prompted, press an
TANK-6000-C226 Embedded System Page 103 Step 5: The Symantec Ghost window appears and starts configuring the system to build an auto recovery parti
TANK-6000-C226 Embedded System Page 104 Step 7: The Symantec Ghost starts to create the factory default image (Figure C-27). Figure C-27: Image Cr
TANK-6000-C226 Embedded System Page 105 Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc. Advanced iEi Feature Auto Recove
TANK-6000-C226 Embedded System Page 106 Step 1: Hardware and BIOS setup. Refer to Section C.2.1. Step 2: Install Linux operating system. Make sure
TANK-6000-C226 Embedded System Page 107 DISKPART>sel disk 0 DISKPART>create part pri size= ___ DISKPART>assign letter=N DISKPART>ex
TANK-6000-C226 Embedded System Page 108 Figure C-31: Access menu.lst in Linux (Text Mode) Step 6: Modify the menu.lst as shown below. Step 7:
TANK-6000-C226 Embedded System Page 109 C.5 Recovery Tool Functions After completing the initial setup procedures as described above, users can acce
TANK-6000-C226 Embedded System Page 2 1.1 Overview Figure 1-1: TANK-6000-C226 The TANK-6000-C226 embedded system is with one VGA port and one HDMI
TANK-6000-C226 Embedded System Page 110 WARNING: All data in the system will be deleted during the system recovery. Please backup the system files
TANK-6000-C226 Embedded System Page 111 Figure C-35: Recovery Complete Window C.5.2 Backup System To backup the system, please follow the steps bel
TANK-6000-C226 Embedded System Page 112 Figure C-37: System Backup Complete Window C.5.3 Restore Your Last Backup To restore the last system backup
TANK-6000-C226 Embedded System Page 113 Figure C-39: Restore System Backup Complete Window C.5.4 Manual To restore the last system backup, please f
TANK-6000-C226 Embedded System Page 114 C.6 Restore Systems from a Linux Server through LAN The One Key Recovery allows a client system to automat
TANK-6000-C226 Embedded System Page 115 C.6.1 Configure DHCP Server Settings Step 1: Install the DHCP #yum install dhcp (CentOS, commands marked in
TANK-6000-C226 Embedded System Page 116 filename “pxelinux.0”; C.6.2 Configure TFTP Settings Step 1: Install the tftp, httpd and syslinux. #yum i
TANK-6000-C226 Embedded System Page 117 Debian Replace the TFTP settings from “inetd” to “xinetd” and annotate the “inetd” by adding “#”. #vi /etc
TANK-6000-C226 Embedded System Page 118 C.6.4 Start the DHCP, TFTP and HTTP Start the DHCP, TFTP and HTTP. For example: CentOS #service xinetd resta
TANK-6000-C226 Embedded System Page 119 Modify: [image] comment = One Key Recovery path = /share/image browseable = yes writable = yes pub
TANK-6000-C226 Embedded System Page 3 1.3 Features The TANK-6000-C226 features are listed below: LGA1155 socket supports Intel® Xeon® E3 / Core™
TANK-6000-C226 Embedded System Page 120 Step 2: Continue to configure the Boot Option Priorities BIOS option of the client system: Boot Option #1
TANK-6000-C226 Embedded System Page 121 NOTE: A firewall or a SELinux is not in use in the whole setup process. If there is a firewall or a SEL
TANK-6000-C226 Embedded System Page 122 C.7 Other Information C.7.1 Using AHCI Mode or ALi M5283 / VIA VT6421A Controller When the system uses AHC
TANK-6000-C226 Embedded System Page 123 Step 5: When the following window appears, press <S> to select “Specify Additional Device”. Step 6:
TANK-6000-C226 Embedded System Page 124 Step 7: After pressing <Enter>, the system will get into the recovery tool setup menu. Continue to fo
TANK-6000-C226 Embedded System Page 125 Appendix D D Hazardous Materials Dis clos ure
TANK-6000-C226 Embedded System Page 126 D.1 Hazardous Materials Disclosure Table for IPB Products Certified as RoHS Compliant Under 2002/95/EC Witho
TANK-6000-C226 Embedded System Page 127 Part Name Toxic or Hazardous Substances and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromiu
TANK-6000-C226 Embedded System Page 128 此附件旨在确保本产品符合中国 RoHS 标准。以下表格标示此产品中某有毒物质的含量符合中国 RoHS 标准规定的限量要求。 本产品上会附有”环境友好使用期限”的标签,此期限是估算这些物质”不会有泄漏或突变”的年限。本
TANK-6000-C226 Embedded System Page 4 I/O interfaces USB 4 x USB 3.0 2 x USB 2.0 Ethernet 1 x RJ-45 for Intel® i217 PHY with AMT 8.0 supported
TANK-6000-C226 Embedded System Page 5 2 x HDD/SSD bay 1 x OLED display 1 x Power button 2 x USB 3.0 connectors Figure 1-2: TANK-6000-C2
TANK-6000-C226 Embedded System Page 6 Figure 1-3: TANK-6000-C226 Rear Panel
TANK-6000-C226 Embedded System Page 7 1.7 Dimensions The physical dimensions are shown below: Figure 1-4: Physical Dimensions (mm)
TANK-6000-C226 Embedded System Page 8 Chapter 2 2 Unpacking
TANK-6000-C226 Embedded System Page 9 2.1 Anti-static Precautions WARNING: Failure to take ESD precautions during installation may result in perma
TANK-6000-C226 Embedded System Page ii Revis ion Date Version Changes 14 March 2014 1.00 Initial release
TANK-6000-C226 Embedded System Page 10 2.3 Unpacking Checklist NOTE: If some of the components listed in the checklist below are missing, please do
TANK-6000-C226 Embedded System Page 11 Quantity Item and Part Number Im a g e 1 Utility CD 1 One Key Recovery CD Table 2-1: Package List Cont
TANK-6000-C226 Embedded System Page 12 Chapter 3 3 Ins tallation
TANK-6000-C226 Embedded System Page 13 3.1 Installation Precautions During installation, be aware of the precautions below: Read the user manual:
TANK-6000-C226 Embedded System Page 14 3.3 Hard Dis k Drive (HDD) Ins tallation 3.3.1 Serial ATA 2.0 Drive Ins tallation To install the hard disk
TANK-6000-C226 Embedded System Page 15 Figure 3-2: HDD Bracket Retention Screws Step 4: Lift the HDD bracket out of the TANK-6000-C226 and slide
TANK-6000-C226 Embedded System Page 16 3.3.2 Serial ATA 3.0 Drive Ins tallation To install the hard disk drive to the SATA 3.0 driver bay, please
TANK-6000-C226 Embedded System Page 17 Figure 3-6: Installing the HDD Step 4: Install the HDD bracket in the same position it was before and tight
TANK-6000-C226 Embedded System Page 18 Step 2: Remove the expansion slot cover. The expansion slot cover is secured to the system with a single ret
TANK-6000-C226 Embedded System Page 19 3.5 AT/ATX Mode Selection AT or ATX power mode can be used on the TANK-6000-C226. The selection is made throu
TANK-6000-C226 Embedded System Page iii Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in ord
TANK-6000-C226 Embedded System Page 20 in standby mode. Remote power control is perfect for advertising applications since the broadcasting time for
TANK-6000-C226 Embedded System Page 21 Step 3: Secure the brackets to the system by inserting two retention screws into each bracket as illustrated
TANK-6000-C226 Embedded System Page 22 To install these devices, connect the corresponding cable connector from the actual device to the correspondi
TANK-6000-C226 Embedded System Page 23 3.8.2 HDMI Device Connection The HDMI connector transmits a digital signal to compatible HDMI display devices
TANK-6000-C226 Embedded System Page 24 Step 1: Locate the RJ-45 connectors. The location of the LAN connector is shown in Chapter 1. Step 2: Align
TANK-6000-C226 Embedded System Page 25 Figure 3-16: DB-9 Serial Port Connector Step 3: Secure the connector. Secure the serial device connector to
TANK-6000-C226 Embedded System Page 26 Step 2: Align the connectors. Align the USB device connector with one of the connectors on the external peri
TANK-6000-C226 Embedded System Page 27 Step 3: Insert the VGA connector. Once the connectors are properly aligned with the insert the male connecto
TANK-6000-C226 Embedded System Page 28 Chapter 4 4 System Motherboard
TANK-6000-C226 Embedded System Page 29 4.1 Motherboard Layout The TANK-6000-C226 embedded system motherboard comes with a number of peripheral i
TANK-6000-C226 Embedded System Page iv Ta b le of Contents 1 INTRODUCTION ...
TANK-6000-C226 Embedded System Page 30 4.2 Internal Peripheral Connectors Internal peripheral connectors are found on the motherboard and are only a
TANK-6000-C226 Embedded System Page 31 4.2.2 Battery Connector (B AT1) 4.2.3 BMC Debug Connector (J2_BMC) PIN NO. DESCRIPTION PIN NO. DESCRIPTIO
TANK-6000-C226 Embedded System Page 32 4.2.5 Fan Connectors (CPU_FAN1, SYS_FAN2) 4.2.6 Flash BIOS ROM Connector (JSPI1) 4.2.7 Flash EC ROM Connecto
TANK-6000-C226 Embedded System Page 33 4.2.8 Flash BMC ROM Connector (SPI1) 4.2.9 OLED Connector (OLED1) 4.2.10 Power on Connector (CN3) PIN NO
TANK-6000-C226 Embedded System Page 34 4.2.11 Serial ATA 3.0 connectors (S ATA1 ) PIN NO. DESCRIPTION PIN NO. DESCRIPTION S1 GND P5 GND S2 SA
TANK-6000-C226 Embedded System Page 35 Connector Type Label USB 2.0 connector Dual USB 2.0 port USB_CON3 VGA connector 15-pin female VGA1 Tabl
TANK-6000-C226 Embedded System Page 36 4.3.4 Ethernet Connectors (LAN3, LAN4) PIN NO. DESCRIPTION PIN NO. DESCRIPTION C1 LAN1_MDI0P C5 LAN1_M
TANK-6000-C226 Embedded System Page 37 8 GND 20 HDMI_GND 9 HDMI_DATA0# 21 HDMI_GND 10 HDMI_CLK 22 HDMI_GND 11 GND 23 HDMI_GND 12 HDMI_C
TANK-6000-C226 Embedded System Page 38 1 VCC 10 VCC 2 USB_DATA- 11 USB_DATA- 3 USB_DATA+ 12 USB_ DATA+ 4 GND 13 GND 5 USB3_RX- 14 USB
TANK-6000-C226 Embedded System Page 39 Chapter 5 5 BIOS
TANK-6000-C226 Embedded System Page v 3.8.5 USB Device Connection ...
TANK-6000-C226 Embedded System Page 40 5.1 Introduction The BIOS is programmed onto the BIOS chip. The BIOS setup program allows changes to certain
TANK-6000-C226 Embedded System Page 41 Key Function - Decrease the numeric value or make changes Esc key Main Menu – Quit and not save changes in
TANK-6000-C226 Embedded System Page 42 The following sections completely describe the configuration options found in the menu items at the top of th
TANK-6000-C226 Embedded System Page 43 Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc. Main Advanced Chipset Boot Security Save &
TANK-6000-C226 Embedded System Page 44 BIOS Information Processor Information Memory Information PCH Information SPI Clock Frequency
TANK-6000-C226 Embedded System Page 45 Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc. Main Advanced Chipset Boot Security Save
TANK-6000-C226 Embedded System Page 46 ACPI Sleep State [S1 only (CPU Stop Clock)] Use the ACPI Sleep State option to specify the sleep state the
TANK-6000-C226 Embedded System Page 47 Wake System with Fixed Time [Dis abled] Use the Wake System with Fixed Time option to specify the time the
TANK-6000-C226 Embedded System Page 48 Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc. Advanced CPU Information Intel® C
TANK-6000-C226 Embedded System Page 49 Intel SMX Technology: Indicates if Intel SMX Technology is supported by the CPU. EIST Technology: Indic
TANK-6000-C226 Embedded System Page vi 5.1.4 Unable to Reboot after Configuration Changes ... 41 5.1.5 BI
TANK-6000-C226 Embedded System Page 50 EIS T [Enabled] Use the EIST option to enable or disable Enhanced Intel SpeedStep® Techonology (EIST).
TANK-6000-C226 Embedded System Page 51 Disabled Disables the on-board SATA controller. SATA Mode Selection [IDE Mode] Use the SATA Mode Selec
TANK-6000-C226 Embedded System Page 52 Enabled Intel® Rapid Start Technology is enabled 5.3.6 AMT Configuration The AMT Configuration submenu
TANK-6000-C226 Embedded System Page 53 Disabled DEFAULT Disable ME unconfigure Enabled Enable ME unconfigure 5.3.7 USB Configuration Use the
TANK-6000-C226 Embedded System Page 54 keyboard can control the system even when there is no USB driver loaded onto the system. Enabled DEFAULT
TANK-6000-C226 Embedded System Page 55 5.3.8.1 Serial Port n Configuration Use the Serial Port n Configuration menu (BIOS Menu 11) to configure the
TANK-6000-C226 Embedded System Page 56 IO=3F8h; IRQ=3, 4 Serial Port I/O port address is 3F8h and the interrupt address is IRQ3,4 IO=2C0h; IRQ=
TANK-6000-C226 Embedded System Page 57 5.3.9 iWDD H/W Monitor The iWDD H/W Monitor menu (BIOS Menu 12) contains the fan configuration submenus and d
TANK-6000-C226 Embedded System Page 58 o +3.3V o +3.3VSB 5.3.9.1 Smart Fan Mode Configuration Use the Smart Fan Mode Configuration submenu (BIOS M
TANK-6000-C226 Embedded System Page 59 Fan start PWM Use the + or – key to change the Fan start PWM value. Enter a decimal number between 1 and
TANK-6000-C226 Embedded System Page vii A.2.2 Cleaning Tools ...
TANK-6000-C226 Embedded System Page 60 Enabled Enabled the console redirection function The following options are available in the Console Redir
TANK-6000-C226 Embedded System Page 61 None DEFAULT No parity bit is sent with the data bits. Even The parity bit is 0 if the number of ones
TANK-6000-C226 Embedded System Page 62 5.3.11 iEi Feature Use the iEi Feature menu (BIOS Menu 15) to configure IEI One Key Recovery function. Aptio
TANK-6000-C226 Embedded System Page 63 5.4 Chips et Use the Chipset menu (BIOS Menu 16) to access the PCH-IO and System Agent (SA) Subsystem configu
TANK-6000-C226 Embedded System Page 64 5.4.1 PCH-IO Configuration Use the PCH-IO Configuration menu (BIOS Menu 17) to configure the PCH chipset. Apt
TANK-6000-C226 Embedded System Page 65 Enabled Power Saving Function support enabled USB Power SW1 [+5V DUAL] Use the USB Power SW1 BIOS op
TANK-6000-C226 Embedded System Page 66 Enabled DEFAULT The onboard High Definition Audio controller is detected automatically and enabled 5.4.2 S
TANK-6000-C226 Embedded System Page 67 5.4.2.1 Graphics Configuration Use the Graphics Configuration submenu (BIOS Menu 20) to configure the graph
TANK-6000-C226 Embedded System Page 68 64M 64 MB of memory used by internal graphics device 128M 128 MB of memory used by internal graphics
TANK-6000-C226 Embedded System Page 69 Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc. Chipset LCD Control Primary IGFX Bo
TANK-6000-C226 Embedded System Page viii Lis t of Figures Figure 1-1: TANK-6000-C226 ...
TANK-6000-C226 Embedded System Page 70 5.4.2.2 NB PCIe Configuration Use the NB PCIe Configuration submenu (BIOS Menu 22) to configure the northbrid
TANK-6000-C226 Embedded System Page 71 Detect Non-Compliance [Enabled] Use the Detect Non-Compliance option to detect non-compliance PCIe device
TANK-6000-C226 Embedded System Page 72 5.5 Boot Use the Boot menu (BIOS Menu 24) to configure system boot options. Aptio Setup Utility – Copyright (
TANK-6000-C226 Embedded System Page 73 Quiet Boot [Enabled] Use the Quiet Boot BIOS option to select the screen display when the system boots.
TANK-6000-C226 Embedded System Page 74 5.6 Security Use the Security menu (BIOS Menu 25) to set system and user passwords. Aptio Setup Utility – Cop
TANK-6000-C226 Embedded System Page 75 Aptio Setup Utility – Copyright (C) 2012 American Megatrends, Inc. Main Advanced Chipset Boot Security Save &
TANK-6000-C226 Embedded System Page 76 A Safety Precautions Appendix A
TANK-6000-C226 Embedded System Page 77 WARNING: The precautions outlined in this chapter should be strictly followed. Failure to follow these pre
TANK-6000-C226 Embedded System Page 78 A.1.2 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of the TANK-
TANK-6000-C226 Embedded System Page 79 A.1.3 Product Disposal CAUTION: Risk of explosion if battery is replaced by and incorrect type. Only certi
TANK-6000-C226 Embedded System Page ix Figure C-8: Building the Recovery Partition ...
TANK-6000-C226 Embedded System Page 80 The interior of the TANK-6000-C226X does not require cleaning. Keep fluids away from the TANK-6000-C226 in
TANK-6000-C226 Embedded System Page 81 B BIOS Me n u Options Appendix B
TANK-6000-C226 Embedded System Page 82 System Date [xx/xx/xx] ...
TANK-6000-C226 Embedded System Page 83 Azalia [Enabled] ...
TANK-6000-C226 Embedded System Page 84 Appendix C C One Key Recovery
TANK-6000-C226 Embedded System Page 85 C.1 One Key Recovery Introduction The IEI one key recovery is an easy-to-use front end for the Norton Ghost s
TANK-6000-C226 Embedded System Page 86 After completing the five initial setup procedures as described above, users can access the recovery tool by
TANK-6000-C226 Embedded System Page 87 partitions. Please take the following table as a reference when calculating the size of the partition. OS
TANK-6000-C226 Embedded System Page 88 o Ubuntu 8.10 (Intrepid) o Ubuntu 7.10 (Gutsy) o Ubuntu 6.10 (Edgy) o Debian 5.0 (Lenny) o Debian 4.0 (E
TANK-6000-C226 Embedded System Page 89 C.2.1 Hardware and BIOS Setup Step 1: Make sure the system is powered off and unplugged. Step 2: Install a
Comments to this Manuals